The NSRRC operates two synchrotron radiation light sources, Taiwan Light Source and Taiwan Photon Source. Both sources employ superconducting radio frequency (SRF) cavities. Recently, occurrences of multipacting events have been encountered during the operation of the SRF modules in both sources, leading to operational challenges. In this report, we provide an overview of the SRF modules in both sources, investigate the multipacting events, and propose potential improvement solutions.